Introduction
Organic vacuum drying device for large-area displays
Technology
Excellent temperature uniformity: ±3℃ (10.5G board)
World's highest drying uniformity: ≤ 10% (10.5G substrate)
Secure layered design for mass production operation
Exhaust system to create uniform vacuum
Specification
Layout : 4260X4890X3085 (10.5G)
Base Pressure : 5X 10-5 torr
Pumping Speed : <2min (@7.5 X 10-5 torr)
Introduction
It is a device that dries, transports, and loads in vacuum conditions before and after the LCD/OLED process.
Technology
Minimize Volume.
Safety is ensured by applying Sensor Dual Type.
Real-time confirmation using CCTV inside the chamber.
O-ring groove shape optimized to prevent metal grinding.
Prevents foreign substances from entering the logistics equipment by maintaining a higher pressure than the PM Chamber.
Gas detector applied to check process gas inflow.
Specification
degree of vacuum : ≤ 5.0 x 10-7Torr (TBD)
Material, Thickness: As per specification (TBD)
Sensor: Apply Sample, Fork, Position detection
Gauge : ATM, Full Range, High, Middle Vacuum Gauge
Sample Type : Face Down, Face UP
After treatment : SBB, Buffing , E.P , Anodizing
Tack Time : 50sec
Lid open : Auto Lid , Crain
Vent : CDA, N2 (Slow, Fast)
Stress, strain: 215Mpa, 5mm or less
Introduction
LManage oxygen and moisture with the circulating gas purifier of the CD/OLED N2 Chamber
Technology
Minimize size.
Purification capacity increased compared to existing purifier (approximately 1.5 times)
Specification
Volume : 5m³ ~ 100m³
PPM : ≤ 1ppm (Oxygen / Moisture)
Type : Touch Panel / Ethernet I.O
Applicable equipment : LCD, OLED TM, Buffer, Oven, etc
Introduction
Real-time static electricity elimination device for high vacuum (vacuum degree constant)
In the OLED manufacturing process, panel transfer and alignment/masking are repeated due to mechanical contact.
Real-time static electricity removal
Technology
Compact Size: Can be installed by modifying the View Port without any additional modifications.
Vacuum degree constant: No separate gas used (Chamber residual gas ionization)
Damage Free: No light or heat generated (OLED Damage Free)
High stability and durability: no light or heat generated
Specification
Operating vacuum degree : 10E-3 ~ 1.0E-5(Pa)
Size : Ø165, H:265
texture : SUS , SS41
weight : 7Kg
Voltage used : DC 4kV , 0.1mA (이내)